One Solution for Infants

The F&P 850 System delivers heated, humidified support across the infant respiratory care continuum.
F&P 850 System with Neopuff T-Piece Resuscitator overview


Resuscitation

Newborn resuscitation aims to establish effective spontaneous breathing or assist ventilation of the lungs within the first few minutes of life. The F&P Neopuff™ T-piece Resuscitator can be used with the F&P 850 System to deliver this therapy.

T-piece resuscitation has been proven to:

  • help protect the lungs from injury by working to provide controlled and consistent PIP1-3
  • establish and maintain functional residual capacity (FRC)4
  • promote normothermia when using heated and humidified T-piece resuscitation.5
 

Product codes

Product Code Description Number in Box
900RD110 Single use humidified T-piece circuit 10
F&P 850 System infant invasive overview
   


Invasive ventilation

Invasive ventilation is a mode of respiratory support that replaces spontaneous breathing in neonates and infants with an artificial airway such as an endotracheal tube.

Delivering heated and humidified gas during invasive respiratory support has several key benefits.

  • Assists the natural defence mechanisms in the airway, which can be interrupted by the presence of an endotracheal tube.6
  • Promotes conservation of energy for growth and development.7,8
  • Supports patient comfort and therapy tolerance.9,10
 

Product codes

Product Code Description Number in Box
RT265 Dual heated infant circuit kit with Evaqua 2 technology and MR290
Auto-fill Chamber (flow > 4 L/min)
10
RT266 Dual heated infant circuit kit with Evaqua 2 technology and MR290
Auto-fill Chamber (flow 0.3-4 L/min)
10
RT267 Dual heated infant circuit kit with Evaqua 2 technology and MR290
Auto-fill Chamber for SLE2000 series ventilators
10
RT268 Dual heated infant circuit kit with Evaqua 2 technology and MR290
Auto-fill Chamber for SLE5000 series ventilators
10
RT269 Dual heated infant circuit kit with Evaqua 2 technology and MR290
Auto-fill Chamber for SLE6000 series ventilators
10
Product Code Description Number in Box
RT225 Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber (flow > 4 L/min) 10
RT226 Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber (flow 0.3 - 4 L/min) 10
RT227 Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber for SLE2000 series ventilators 10
RT228 Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber for SLE500 series ventilators 10
F&P 850 System infant CPAP overview


Continuous positive airway pressure

Continuous positive airway pressure (CPAP) is a mode of noninvasive respiratory support that provides a continuous distending pressure throughout the respiratory cycle to spontaneously breathing patients.11,12

There are several key benefits of CPAP therapy for infants.

  • Maintains functional residual capacity.11,13
  • Reduces the work of breathing.13,14,15
  • Decreases the need for mechanical ventilation.16,17
 

Product codes

Product Code Product Description Number in Box
BC151-10 Infant bubble CPAP system including inspiratory heated breathing circuit with auto-fill chamber, pressure relief manifold & bubble CPAP generator (connects to T-bar interface) 10
BC161-10 Infant bubble CPAP system including inspiratory heated breathing circuit with auto-fill chamber, pressure relief manifold & bubble CPAP generator (connects to F&P interface) 10
RT265 Dual heated infant circuit kit with Evaqua 2 technology and auto-fill chamber (flow > 4 L/min) 10
F&P 850 System infant Optiflow nasal high flow overview


Optiflow Junior nasal high flow

Nasal high flow (NHF) is a mode of noninvasive respiratory support that delivers high flows of blended air and oxygen through an unsealed nasal interface.18

NHF therapy for infants provides the following benefits.

  • Reduces anatomical dead space.19
  • Dynamic positive airway pressure.20,21,22
  • Improves patient comfort.23,24
 

Product codes

Product Code Description Number in Box
RT329 Single limb infant breathing circuit kit with pressure relief valve 10
RT330 Optiflow Junior breathing circuit kit 10
RT331 Optiflow Junior ventilator circuit kit 10


Other Optiflow platforms


Optiflow nasal high flow can also be delivered with the F&P 950 System and the Airvo 2 high flow system.
Close up of a person’s hand operating the F&P 950 System touch screen

F&P 950 System

A next generation, premium performance heated humidification system that's easy to set up and use.

F&P Airvo™ 2 providing respiratory support to a patient in a hospital environment

Airvo 2 nasal high flow system

A humidification system and flow source designed to deliver Optiflow nasal high flow therapy.

 
Contact your F&P 850 representative
If you have an enquiry about our products, please provide the following information so a Fisher & Paykel Healthcare representative can contact you. For further details on how this information will be used, see below or go to our privacy statement.

I consent to Fisher & Paykel Healthcare keeping me informed about new F&P products, clinical updates, events and promotions on the following topics:




Enter security code:*