Nivairo RT045 Full Face NIV Mask

Nivairo™ RT045

Anti-asphyxiation Valve Version

Key Features:

  • Single limb non-vented full face mask with an anti-asphyxiation valve for safety in case of ventilator failure
  • RollFit™ seal adapts to different face shapes and minimizes pressure on the bridge of the nose
  • TubeFit™ zones for placement of a nasogastric or orogastric tubes
  • ErgoFit™ with easy clips and breathable fabric to help with fitting and adjusting
  • Available in four mask sizes: extra small, small, medium and large

Product Codes

Part No Description Quantity
RT045XS Non-vented hospital full face mask with anti-asphyxiation valve; Extra small 10/box
RT045S Non-vented hospital full face mask with anti-asphyxiation valve; Small 10/box
RT045M Non-vented hospital full face mask with anti-asphyxiation valve; Medium 10/box
RT045L Non-vented hospital full face mask with anti-asphyxiation valve; Large 10/box
RT045 Specifications
Mask Type Non-vented with anti-asphyxiation valve
Operating Pressures 4 - 25 cmH2O
Recommended F&P 850™ System Breathing Circuits RT219
Product Use Single-patient use; maximum 14 days
Materials Silicone, Acetal, Polycarbonate, Nylon, Elastane, Polyester, Polyether Polyurethane Foam, Polyester Polyurethane Foam
Destruction Incineration, or according to hospital protocol
Classification Class II

 

 

Nivairo Fitting Guide

Application:

  • For use with single limb BiPAP or ventilator systems where venting is provided in the circuit through the exhalation port
  • Also for use with flow driver CPAP systems with provided PEEP valve

Product Codes

Part No Description Quantity
RT045XS Non-vented hospital full face mask with anti-asphyxiation valve; Extra small 10/box
RT045S Non-vented hospital full face mask with anti-asphyxiation valve; Small 10/box
RT045M Non-vented hospital full face mask with anti-asphyxiation valve; Medium 10/box
RT045L Non-vented hospital full face mask with anti-asphyxiation valve; Large 10/box
RT045 Specifications
Mask Type Non-vented with anti-asphyxiation valve
Operating Pressures 4 - 25 cmH2O
Recommended F&P 850™ System Breathing Circuits RT219
Product Use Single-patient use; maximum 14 days
Materials Silicone, Acetal, Polycarbonate, Nylon, Elastane, Polyester, Polyether Polyurethane Foam, Polyester Polyurethane Foam
Destruction Incineration, or according to hospital protocol
Classification Class II

 

 

Resource download list

Nivairo Application Guide - PM-617261

(PDF 0.2MB)

Download

Nivairo RT045 User Instructions

(PDF 3.8MB)

Download