Critical care environments: intensive care, high dependency, emergency rooms, labor and delivery, neonatal intensive care units, special care baby units.
The humidity performance in Invasive Mode is ≥ 33 mg/L. In Mask Mode, the humidity performance is ≥ 12 mg/L. In most cases, humidity delivery will be higher than these values, with the actual humidity delivery depending on environment conditions, respiratory gas properties and flow source settings.
The humidifier should take less than 30 minutes to reach the set dew point, but it will get close much quicker than this.
Using a damp cloth, clean the heater-wire adapter with either isopropyl alcohol or normal dishwashing detergent. NOTE: Do not immerse the heater-wire adapter in any liquid. This product is not designed for an autoclave sterilization process.
Using a damp cloth, clean the MR850 Humidifier with either isopropyl alcohol or normal dishwashing detergent. For accessory cleaning guidelines, refer to the User Instructions accompanying each accessory. NOTE: Do not immerse the humidifier or accessory electrical connectors in any liquid.
The F&P 850 temperature probes require reprocessing between patients. Refer to the temperature and flow probe user instructions for a list of cleaning options.
The inspiratory limb of F&P Evaqua 2™ circuits has insulating MicroCell™ technology preventing gas from cooling and condensing in the circuit. The expiratory limb has Evaqua™ technology allowing water vapor to diffuse through the limb wall before it has an opportunity to condense into liquid water. These integrated technologies lead to significantly less condensation compared with conventional heated humidifier circuits and reduce the need to break the circuit to empty condensate.
F&P Evaqua 2™ incorporates technology that allows water vapor to diffuse through the material of the expiratory limb. Viruses and bacteria, including incredibly small virus particles, cannot permeate or diffuse through the material.
The table below shows the F&P 850 circuits that include a respiratory filter.
Note: Inspiratory position represents the filter attached to the inspiratory port of the ventilator, and the end-expiratory position represents the filter attached to the expiratory port of the ventilator. Not all filters and circuit kits are available in all countries. Consult your local Fisher & Paykel Healthcare representative for information on availability.
Find clinical evidence and practice guidelines for delivering nasal high flow (aka HFNC) therapy.
Providing Optimal Humidity for intubated patients
Featuring under nose NIV masks (F&P Visairo) and full face NIV masks - (F&P Nivairo), with vented and non-vented options to suit your hospital NIV mask needs.
Establish effective spontaneous breathing or assist ventilation of the lungs
Noninvasive respiratory support that provides a continuous distending pressure
Respiratory support that replaces spontaneous breathing
Noninvasive respiratory support that delivers high flows of blended air and oxygen
Designed to work in harmony with the way patients naturally breathe while they sleep
F&P SleepStyle - designed to strike the balance between comfort and effective treatment
We value your privacy. Our websites and applications use cookies to function properly and securely.